BoonDocker – 1585 Hollipark Dr. Idaho Falls, ID 83401 – 208-542-4411 / 877-522-7805
www.boondockers.com – email: [email protected]m – fax: 208-524-7381
Revised 05-07-07 Page 7 of 16
Selecting Stats from the Main Menu will first display the following screen with real “Run-time” data (current
conditions):
Run 35/40 10.2NA
5500 MD 10
1
st
line
Run
Run” indicates display is in Run mode. If in capture mode, “Cap” will be displayed.
35 Input duty cycle in percent
40 Output duty cycle in percent
10.2 Current Boost Pressure
N If “N” displayed, Nitrous is on
A If “A” displayed, Accelerator Pump Fuel adjustment is on
2
nd
line
5500
RPM (note, if the engine is shut off, the last recorded RPM may be displayed)
MD Engine Load. LO, MD, or HI will be displayed.
These bars are a graphic display of LO, MD, or HI as shown below:
LO
MD
HI
10 Current Fuel Adjustment
Run/Capture mode:
Left-Arrow button : Sets Capture Mode, “Cap” will be displayed and the current data will be frozen on the
display. The capture occurs on the display when the button is released (data will continue to
be captured if the button is held down). It will stay in capture mode (data will remain frozen)
until the Right-Arrow is pressed to return to Run mode or until the Control Box is re-
powered. If the Stats menu is re-entered before the engine is shut off and the box is in
Capture mode, the last captured data will be displayed.
Right-Arrow button: Clears capture mode (captured data will be lost!) and sets Run mode
. “Run” will be
displayed and real-time data will be displayed. Note: The Button Mode can also be
configured to Capture the Status screen Press SEL to go to the next screen: Stats: MAX.
3.2 Stats: MAX
Any button press from the Run screen will go to the next Stats screen which is the Max screen, displaying max
RPM, Duty Cycle In from the sled’s ECU, and Duty Cycle Out to the injectors.
MAX:DCIn/Out Clr.
5500 35/45 YÆN.
MAX: 5500 Max rpm
DCIn 35 Max Duty Cycle Input from sled’s ECU.
DCOut 45 Max Duty Cycle Output to the injectors.
These max values will be saved when the box is shut off so they will remain the next time this screen is displayed
even if the box is re-powered. Peak values or “spikes” are filtered by finding the average during a certain time-
window. Therefore, a maximum must be held for at least 1 second to be recorded and displayed properly.
Use the arrow keys to move the cursor between Y and N. Pressing SEL when the cursor is on Y will clear the max
values. Pressing SEL when the cursor is on N takes you to the next screen: Stats: N2O/TPS.